Developer Toolbox:
New Product Information for Indigo2, Power ChallengeM R8000 and upgrades


******************************************************************************
                        CUSTOMER SERVICES ENGINEERING
                        NEW PRODUCT INFORMATION (NPI) 
*****************************************************************************

Title:  New Product Information for Indigo2TFP, Power Challenge M and Upgrades

Information Provided By:  Frank Demcak

Date: 12-20-94  Revised 01-04-95

Location: A snapshot of all NPI documents sent is in:

          csestuff.csd:/user/Knowledge/Archive/NPI

==============================================================================

 		NEW PRODUCT INFORMATION TEMPLATE

Title: New Product Information for Indigo2TFP, Power Challenge M and upgrades.

I. Product Description:

    The Indigo2TFP and Power Challenge M (D-75301-S2-1) are the TFP ready
    Indigo2 products. The engineering project called Teton developed these
    TFP products.  These products address the needs of heavy computational 
    users with extreme performance.  The new MIPS R8000 processor module 
    provides two integer and two floating point units with 2MB of global 
    streaming cache.  The product integrates a new TFP (MIPS R8000) processor 
    module, IP26 mother-board and requires an newer revision power supply.  
    These products are available as systems and upgrades (HU-TWOTFP) to 
    existing platforms. This architecture requires the use of the new 64 bit 
    IRIX called 6.0.1 .

II. Dependencies/Compatibility Information

    These TFP products will only run the 64 bit IRIX called 6.0.1 or later.
    The TFP architecture and 6.0.1 generate and operate on 64 bit applications
    and data sets.  IRIX 6.0.1 will execute 32 bit applications written 
    under IRIX 5.2 or earlier with reduced performance. 

    The New Product Information document for 6.0.1 lists the know bugs unique 
    to IRIX 6.0.1.  Due to the aggressive schedule some peripheral driver 
    support will become available in the next 6.x release.

    The Power Indigo2 and Power Challenge M have a SIMM height requirement 
    in SIMM banks B and C.  These SIMM banks are locate under the new R8000
    processor module and must not exceed 1.27 inches or 32mm.  Some SGI and 
    third party memory vendors have shipped Toshiba 32MB SIMM memory that 
    exceeds this requirement.  There is a process for SSEs to exchange 
    taller memory for memory that has been pre-screened for this upgrade 
    requirement.  32MB Toshiba memory SIMMs can be screened for height 
    by physically measuring the height of memory in your inventory or by 
    ordering the low profile SIMMs.

    The HU-TWOTFP upgrade product will install in any existing Indigo2 or
    Challenge M system.
    
    Based on the IRIX 6.0.1 release the following peripherals and software 
    products may not work.  Keep in mind that the hardware buses and 
    interfaces have not changed with the new IP26 however some drivers have 
    not been ported or tested.
    
    Incompatible Products
    ---------------------
    3270 Emulator               not tested	
    4DDN                        device driver not ported
    4DLT                        needs DLPI to function
    5080                        device driver not ported
    CASEVision/Clearcase        device driver not ported
    Epoch					    device driver not ported
    InPerson                    not tested
    IRIS Channel Adapter        device driver not ported
    Japanese Language System    no plan
    OSI                         device driver not ported
    Pascal                      not tested
    SNA Server                  device driver not ported
    SNA LU 6.2                  needs SNA Server
    Starter Video Development	N/A
    SX25                        device driver not ported
    Token Ring                  device driver not ported
    Trusted IRIX                no plan
    Volume Manager              device driver not ported
    
    Obsolete Products
    -----------------
    IEEE-488                    obsolete
    
   
    **IMPORTANT NOTE**  Additional information regarding the IRIX 6.0.1 
    software release is available in Donna Yobs IRIX 6.0.1 MR Information 
    NPI published December 21, 1994.


III. Product Numbers (Marketing Codes)

   Systems and Upgrade marketing Codes
    ---------------------------------------------------------
    WB-TWOTFPEX2     Power Indigo2 R8000, Extreme Graphics, 64MB memory, 
                                    2GB disk, 20" Mon
    WB-TWOTFPXZ2     Power Indigo2 R8000, XZ Graphics, 64MB memory, 
                                   2GB disk, 20" Mon
    D-75301-S2-1     POWER CHALLENGE M,  64MB memory,
                                   2GB disk
    HU-TWOTFP        UPGRD TFP CPU FOR INDIGO2/CHALL M

  Contents of Upgrade kit
  -----------------------
    HU-TWOTFP        UPGRD TFP CPU FOR INDIGO2/CHALL M

    024-0859-001     LABEL MOD NO. TFP IND2 UPGRADE
    024-0531-001     LABEL SHIPPING ATTENTION SGI
    024-0858-001     LABEL SYSTEM R8000 SGI INDIGO2
    030-0519-003     PCA TETON TFP CPU UPGRADE
    030-0659-002     PCA IP26
    042-0101-001     LINER NOMEX R8000
    090-0009-001     SHIPPING CONTAINER  VME PCB
    090-0069-001     SHIPPING CONTAINER BOX 20X20X15
    090-0088-001     SHIPPING BOX PCB 12.25"X9.25"X3"
    090-8022-001     SHIPPING BOX POWER SUPPLY SPARE
    7270857          SCREW M3X30MM PAN HD PHL DR INT SEM
    7270855          SCR M3X3/8 LG PHND PHH STL ZNC
    9430814          POWER SUPPLY 74AC/DC 406W 6 OUTPUT Rev S
    007-2596-001     MNL FLYER TETON UPGRADE INSTALL
    813-0302-002     CD PACK IRIX 6.0.1
    108-0130-001     MNL PWR INDIGO2/CHALLENGE UPG INST

    RMA-HU-TWOTFP    RMA PACKET I2 TO POWER I2 UPGRD

    108-0130-001     MANUAL PWR INDIGO2/CHALLENGE UPGADE INSTRUCTIONS

  List of Unique Spares
  ---------------------
    013-1208-001       SPARES ASSY TETON/IP26/AUDIO
    030-0519-003       PCA TETON TFP CPU UPGRADE
    9430814            POWER SUPPLY 74AC/DC 406W 6 OUTPUT Rev S

  Low Profile 32MB SIMM if needed
  -------------------------------
    9010000            SIMM 8MX36 32MB LOW PROFILE (see section XI.)
   

IV. Training plan

    This is a simple SSE upgrade requiring the skills of an SGI SSE that
    has previously stripped an Indigo2 system.
    There will be an update to the Indigo2 Maintenance Manual self
    study manual in Q3 95.  This document will be available through
    Corporate Training and Development when complete.
 
    Until the maintenance course notes are complete the Indigo2TFP and 
    Power Challenge M Upgrade Instructions are well written and would 
    enable any SSE to install the TFP upgrade.
 
    Also, the Power Indigo2 and Power Challenge M Upgrade Instructions, 
    IRIS Indigo2 Technical Report (includes R8000 specs) and other Indigo2 
    related documents will be shipped to service sites world-wide in late 
    December.
    
    Updates have been broadcast on the CSD monthly video covering the
    unique features of the TFP upgrade and issue SSEs should be aware of.

V. Documentation

    There are the documents related to the Indigo2TFP and Power
    Challenge M products :

    108-0130-001     POWER Indigo2 and POWER CHALLENGE M
                            Upgrade Instructions (reviewed by CSD)
              
    007-2546-001     MANUAL PWR CHALLENGE M OWNERS GUIDE

    007-2596-00l     FLYER TETON UPGRADE INSTALL
                     (Note about SIMMs and Audio Bd)

    007-    -        There will be no updates to the Indigo2 Owner's 
                      Guide.  Systems will ship with the Indigo2 
                      Owner's Guide.  There weren't enough differences 
                      in the products to justify making changes to 
                      existing manuals.

    SC4-W4D-6.0.1    IRIX WORKSTATION CD 6.0.1 (will ship with TFP systems)

    813-0302-002     CD PACK IRIX 6.0.1        (will ship with TFP upgrades)

    The installation instructions will be included in the installation package.

    T4-IND2          Indigo2 Maintenance Student Workbook(updated Feb 95)

    This document and related papers will be available on the CSD Web Server 
    at:
             http://www.csd/Products/hdw/teton 

    Sales collateral from product marketing available through sales channels:

    Power Indigo2 Indigo Family Data Sheet         PWR-INDIGO2-DS(10/94)
    Indigo2 Product Guide                          INDIGO2-TM-GD(09/94)
    IRIS INDIGO2 Technical Report (version 2.0)

VI. Technical support delivery issues (Complexity of support expected)

    This product is structured in the same fashion as the current Indigo2
    and Challenge M.  The really unique features are the mother-board and
    TFP (R8000) processor module. The installation instructions for the
    upgrade show how to remove and install the processor and mother-board.  

    The existing NAFO Support products are available for this product 
    including; Full Extended Warranty, Basic Extended Warranty, Parts Care,
    IRIXCare, Full Support, Basic Support and On-site parts care.

    The product is an SSE-only installation due to the complexity of the 
    mother-board removal and to insure the credited components(R4k PM, IP22) 
    are returned to manufacturing in Mountain View, California.

    All areas of expertise can expect to receive customer calls on this
    product as we do with the current Indigo2 family.

    The only tools required to upgrade or maintain this new configuration
    are a wrist strap, 6mm nut driver and #2 philips screw driver.
    Although the installation manual and future training materials may
    be helpful to the novice a current SSE will have no problems
    maintaining or upgrading these systems.

    **IMPORTANT NOTE** If low profile SIMM memory is required to complete 
    the upgrade, the SIMMs removed from the system must be returned to 
    logistics.   Do not put the removed memory in the box with the IP22 and 
    R4400 processor module being returned to Mountain View. 

    The Indigo2TFP and Power Challenge M will be spared at the 
    030-xxxx-xxx parts level except for the mother-board and audio module 
    which will be at the 013-xxxx-xxx level.  See the unique parts in 
    Section III for details.

    Non-SGI/third party SIMMs that do not meet the 1.27inch/32mm height 
    requirements should be dealt with by the customer with their vendor.

VII. Marketing Information

    This product is aimed at the 3D CAD modeling, animation, and interactive 
    data analysis markets. Although not advertised, the IP26 contains a ECC
    single bit corrected memory system that will support up to 640MB 
    of main memory. This configuration supports large data arrays which can 
    be accessed very quickly with extra insurance against incidental data 
    corruption.

    The approximate projected shipments for Indigo2TFP,  Power Challenge M 
    and upgrades are:

     For Upgrades world wide.

        200 units Q2
        250 units Q3
        50  units Q4

    For Indigo2TFP systems.

        275 units Q2
        350 units Q3
        500 units Q4 

     For Power Challenge M systems.
        25  units Q2
        25  units Q3
        25  units Q4

    The NAFO price book currently lists both the Indigo2TFP and Power 
    Challenge M products as well as the upgrade.  A number sales brochures 
    have been printed that graphically show the product like the Indigo2 
    Product Guide featuring the Power Desktop.  The IRIS Indigo2 Technical 
    Report has been rewritten with R8000 features.  The sales Data Sheet for 
    the Power Indigo2 family lists features and environmental specifications 
    on the back cover. All of these documents can be gotten through your sale 
    representative.  Listed below are some of the more important environmental 
    specifications:

      Power Requirements           100-120/200-240VAC
      Heat Dissipation             1000 BTU/HOUR
      Ambient Temperature          +13 to +35 degrees C operating
                                   -10 to +65 degrees C non-operating
      Relative Humidity            10% to 80% operating no condensation
                                   10% to 95% non-operating no condensation
      Altitude                     10,000 feet operating
                                   40,000 feet non-operating
      Vibration                    .02 inches, 5-19HZ
                                   .35G, 19-500HZ
      
    The product marketing manager for this Power Challenge M is Don Galles 
    and Raj Segal for Power Indigo2 and the TFP Upgrade.


VIII. Upgrade Policy

    This is a customer purchased upgrade and an SSE-only install.
  
    This upgrade can be installed on any revision Indigo2 or Challenge M system.

    Installation instructions, prepaid shippers and RMA documents are shipped 
    with the Upgrade package.

IX. Known Bugs

    See SIMM Memory Exchange Process (XI.) and FIB to be written.
    See FIB on "Fast IU test failure" to be written.
    See on-line release notes on 6.0.1
    Also see Section II for incompatible or untested products.

	Hardware problems and issues:

        1. When swapping the IP26 for the IP22 be sure to properly seat
           the EISA Backplane before re-installing ESIA cards.  Symptoms
           may be: No graphics or power and reset button doesn't function.

        2. The new TFP CPU module covers the power connector near the 
           front of the machine so the TFP CPU Module must be lifted to
           connect or disconnect the power supply connections.

        3. Note that it is possible to push the power supply connectors
           onto the mother-board connector pins and have the pins miss
           the connector sockets and insert into the connector strain-relief.
           The connection will look good until you look at it from above
           the connector. The system will not power up or show any indication
           of running power on diagnostics.

        4. The TFP CPU module flex connector that attaches to the mother-board
           is somewhat fragile and should be rocked into the mating mother-
           board very carefully.  If the cable connection is not properly made
           the system may not run power on diagnostics and the health/power 
           LED will remain red.

        5. The audio board is not shipped with the upgrade so make sure that
           you remove it from the IP22 and move it to the IP26 before returning
           the credited parts.

        6. Some Teton Systems fail power-on Fast IU test.  Pushing the reset 
           button will allow the machine to complete power-on diagnostics and 
           boot IRIX.  This will affect some customers more than others, e.g. 
           Japanese or secure defense customers, who are usually required to 
           turn off computer equipment at night.
          Also,
           some systems intermittently fail the Fast IU test when running the
           customer version of ide.  The Fast IU test in ide is the same test 
           run during power-on diagnostics.  Pushing the reset button and 
           rerunning ide usually passes the Fast IU test.
           There is a letter from product marketing that describes how to get 
           around the error condition and explains that a replacement IP26
           PROM will be shipped to correct this error.  This letter will be
           included in all units shipped with this problem.

X. Follow-Up

    On a weekly or bi-weekly basis we will be feeding field call summaries
    to the product division to tell them how the TFP systems are performing 
    We will be using an exiting tools via the World Wide Web 
    (http://www.csd/Projects/Callsum/Reports/Home.html)

    For international tracking we will be relying on email and conversations
    with International support centers for service related data.

    At the time of release there are no know show-stopper issues in the
    hardware or software.  

    A FIB will be written that details the SIMM Height issue.

XI. SIMM Memory Exchange Program

    Late in release of the Indigo2 TFP upgrade package  we found that SGI 
    and some third-party manufacturers have shipped some 32MB SIMMS that 
    will not fit under the TFP CPU module in memory banks B and C. 
    
    The height specification for Indigo2 SIMMS is 1.27 inches or 32mm high.
    Toshiba shipped 32MB SIMMs that were about 1.33 inches or 34mm.
    Although the amount of interference is only about 1/10th of an inch, 
    it could be enough to flex the CPU module or mother-board.
    Only a small number of the tall Toshiba 32MB SIMMs were shipped and
    even fewer were shipped in multiple memory banks.  System configured with 
    one bank of tall Toshiba 32MB SIMMs can be reconfigured by moving the tall 
    memory to Bank A of the mother-board. 
    
    There may be cases where customers have ordered 256MB or 384MB and they
    could have two banks of memory that are too-tall. In this case it would be 
    necessary for you to order a set of 4 replacement 32MB SIMMs that meet 
    the 1.27 inch specification.  Only systems with 256MB or 384MB of SIMM
    memory could be suspected of having this problem.  HINV can be used to 
    verify the amount of memory a customer's machine has prior to placing any 
    orders.

    Early January we will have a pre-punched non-electro-static sensitive card
    that you can use to screen or check the size of SIMMs you have.  
    I will be advancing copies of these gauges to service providers world 
    wide as well as one will going into every TFP upgrade kit.  There is also 
    a gauge silk screened on the insulator card that is screwed down on top of 
    the TFP CPU Module.  

    We have created a part number for replacement SIMMs on a call-by-call 
    basis.   The SIMM part number is 90100000. If these SIMMs are requested 
    they must be returned to logistics against the same call ID opened to 
    request the SIMMs.  The part number used to return the tall memory would 
    be the old SIMM part number 9016824.
    
    If you are already on-site and doing the upgrade and find that the customer 
    has two banks of SIMMS that are too-tall , the upgrade can be completed 
    with one bank installed in Bank A and a replacement set of SIMMs ordered 
    for Bank B or C.
    
    If you know the customer's machine  has 256 or 384MB of memory you might
    pre-order 32MB SIMMs . 

    REMEMBER, THE MEMORY MUST BE RETURNED ON THE OPEN CALL ID WHETHER IT WAS
    USED OR NOT.  DO NOT RETURN THE 32MB SIMMS YOU ORDERED AGAINST THE 
    UPGRADE IN THE SHIPPING  BOX WITH THE RETURNING PARTS.
    
    A final note on these TFP upgrades: our research indicates that the 
    highest percentage of systems that may run into this SIMM height problem 
    are located in Japan since most of their orders include large memory 
    system.  Less than 200 systems world-wide could have this problem and 
    only a few of those will be upgraded. There may be a few in the US and 
    Canada however we don't think there are any in Europe or the UK.
    
    If you find that a customer has purchased their own memory and it exceeds
    the height specification, the customer will have to work with their vendor
    or with their salesman for special consideration.
    
XII. Credited Parts Return Process

    IMSD Manufacturing has set up an RMA packet for Domestic(NAFO) and 
    International parts return.  This packet is used to return the IP22,  
    TFP CPU Module and power supply removed from the customers machine.  
    There is an airbill, address label,  RMA #  and customs forms to return 
    the credited components (customer has been pre-credited for the returning 
    parts).   A separate set of forms need to be filled out for each returning 
    part, not one form for the entire package.  This will help eliminate 
    missing parts in the larger packages and make it easier for customs.  

    The SSE installer is responsible for getting the returning parts
    to the shipper and back to manufacturing.  For the first quarter all 
    credited parts will be coming back to Mountain View, however future 
    upgrades may be returned to other manufacturing sites world wide.  
    Follow the instructions enclosed in the RMA package.  The shipping 
    instructions sheet has a contact and phone number if you run into any 
    problems with the RMA process.

    Once you have sent the parts to SGI, send an e-mail to Randy Bresee 
    at randyb@csd, referring to the HU-TFPTWO Upgrade and informing him of 
    the branch office/subsidiary and the RMA number.  This will create a 
    double path to enable us to better track the parts to ensure you get 
    credit and minimize the chances of your parts getting lost in the system.